Sunday, April 7, 2013
Law Students get Integrated Technology and Refined Architecture at Chicago's Kent College of Law
Lighting, Branding and Technology at the InterContinental Hotel in Miami
The exterior façade and lobby of the InterContinental Miami has been renovated to create an “electric” guest experience. Accomplished through new lighting, branding and technology, the hotel draws inspiration from the Miami club scene and art district. A 19-story digital canvas of LED lights creates a larger-than-life video display on the tower while a 550 square foot hi-res display welcomes guest as they enter the porte cochere. The porte cochere has been wrapped with over 6,000 LED nodes set behind an opaque layer of new glazing, creating a dynamic entrance sequence for the guest.
The transformed lobby utilizes colors, textures and technology to engage the guest by allowing them to interact with the building. A field of color changing, back-lit glass ‘Pods’ create seating clusters that focus around interactive touchscreen surfaces while highlighting the existing world’s largest Henry Moore sculpture. LED monitors continue the animated exterior theme throughout the lobby, reception and elevator lobby. These monitors display artful media, including a library populated by guest photos.
The entire project is orchestrated by a central control system. The interior and exterior elements interact as one color changing, media displaying show, making the guest experience unforgettable.
This project was a design collaboration between Thomas Roszak Architecture and Lohan Anderson.
Friday, May 11, 2012
Adler Welcome Gallery Wins Chicago AIA Small Projects Award
Chicago Architect Magazine
Friday, March 2, 2012
CS Interiors: An Otherworldly Welcome
![]() |
MOODY BLUES Colored lighting sets the tone for exploration at the Adler's new Welcome Gallery. |
Article from CS Interiors - Winter 2012
http://digital.modernluxury.
Monday, December 12, 2011
IIT Students Study Market Ready Alternates to Chicago Spire
Students from the School of Architecture at the Illinois Institute of Technology (IIT) worked with Adjunct Professor Thomas Roszak, as part of a comprehensive building design studio to study the current market solution for the old Chicago Spire site, at 400 N. Lake Shore Drive. The original project designed by Santiago Calatrava was to be 150 stories and 2000 feet tall, and contain 1200 condos, but was never built due to the real estate crisis. With new input from some key Chicago residential developers including Hines Development, Related Midwest, and Mesa Development, the students studied what is market ready in today’s housing climate.
It was determined that two towers 40-stories tall with approximately 400 rental units each may be feasible today. Construction costs were targeted at $160-180/gsf and land costs of $20 Million for each tower.
The students compared the Chicago Spire, which would have cost well over $1 Billion in construction costs and supported a land cost of an additional $150 Million, to their new projects which would cost approximately $150 Million per tower, including land. “It is amazing what a different world it is today as compared to 2007,” commented 4th year student Denys Petrenko, “and this study really puts into perspective what the future of residential development will look like in the years to come.”
Erik Shultz, another 4th year student noted that "the strong rental market makes this project feasible, and the fact that some banks can provide this level of financing to well established residential developers that can provide at least 25% of the equity needed, which in this case would be approximately $40 Million per tower." Erik and 13 of his fellow classmates, in their 4th and 5th year of their Bachelor of Architecture, analyzed hard and soft costs of similar projects. They also prepared plans, renderings, study models, animation, budgets, proformas, zoning analysis, code analysis, marketing analysis and detailed construction details.
A final architectural crit was done in front of some Chicago area professionals including architects, engineers, and contractors specializing in rental housing, that gave informative real world insight into the design of these residential towers and the future of high-rise housing in Chicago, at least in the short-term.
A learning experience for all...
Thursday, September 22, 2011
Sunday, September 4, 2011
Adler Planetarium Welcome Gallery Design Team
Thursday, July 14, 2011
Sunday, June 26, 2011
Thomas Roszak Architecture Designs New Welcome Gallery at the Adler Planetarium in Chicago
Using architecture in a way to incorporate a client’s vision, even the most “out of this world” concepts, can be in the realm of the possible. The architectural and media contributions to the Welcome Gallery immensely enhance guests’ overall experience at Adler Planetarium. Thomas Roszak Architecture, LLC, is proud to have their architectural and design contributions aide in reaching Adler’s ultimate goal of creating an exciting and curiosity-evoking visit sure to create buzz and desire for guests to return for more learning and space exploration!
Please view more images here.
Thursday, June 9, 2011
Roszak Designs New Gallery at the Alder Planetarium
Saturday, June 4, 2011
7RR, a green home by Thomas Roszak Architecture
Thursday, February 3, 2011
Green, Modern and Affordable House

Monday, October 25, 2010
IIT students assist Lycée Français de Chicago on future school design and construction
Our firm, Thomas Roszak Architecture, worked with the Lycée Français de Chicago (LFC) and students from the Illinois Institute of Technology (IIT) as part of a comprehensive building design studio to study the future facility needs of this private pre-K thru 12 French school. With help from LFC’s facility board we studied various sites that were proposed by Jones Lang LaSalle, their real estate consultant, to determine actual site requirement in terms of size and access. We studied and improved on preliminary programs to pinpoint space allocation between grades and support spaces. This is a school with needs for over 700 students. The book The Third Teacher was a required reading as preparation for the assignment. We studied hard and soft costs and made recommendations that will surely be implemented into the final design and construction. The 14 students, in their 4th and 5th year of their Bachelor of Architecture program also prepared plans, renderings, budgets, proformas, zoning analysis, code analysis, and detailed construction details. A final architectural crit was done in front of the LFC board and other Chicago area professionals including architects, contractors, and school officials that gave informative real world insight into the design of this school and the future of education in general. A learning experience for all...


Click here to download a PDF with more images.
Sunday, October 17, 2010
An Engineer Imagines in Glass
An interview discussing the structural glass stair design between Architect, Thomas Roszak principal at Thomas Roszak Architecture, LLC and Structural Engineer, Koz Sowlat, principal at Sowlat Structural Engineers, Chicago. See also previous blog on this project.
Describe the Members and Materials:
· Laminated glass: Each structural panel is Laminated Glass; made of ASTM C 1048 Fully Tempered (FT) and Heat Strengthened (HS) glass plies bonded with a clear interlayer in conformance with ASTM C1172.
· Composition: Vertical panels, landing panel, and treads, all have the same laminated glass composition, each measuring 1 ½ in. thick, and composed of the following three plies: 1/2" FT + 1/2" HS + 1/2" FT. A combination of glass types was selected to provide appropriate performance under service conditions as well as under extreme conditions.
Describe the Structural Analysis and Design:
· Analysis method: Three-dimensional finite element analyses were used to determine stresses and displacements, under design loads. For vertical panels, large-deformation, non-linear analysis was used, to account for member flexibility.
· Design method: At each element, von Mises stress (vector sum of principal stresses) was determined and maintained below the allowable stresses.
· Allowable Stress: For each load case and for each load combination, von Mises stress within the structure was limited to 5,000 pounds per square inch for FT glass, except that stress in FT with surface conditioning was limited to 2,500 pounds per square inch. Fully tempered glass is produced with a residual surface compression of 9,700 pounds per square inch, reducing the likelihood of surface tension, and inhibiting opportunities for crack growth.
· Composite Action: Based on standards recommended by The Institution of Structural Engineers, London, UK, entitled: “Structural Use of Glass in Buildings,” published in 1999, each panel was analyzed as if a solid material.
· Redundancy: General structural integrity check was provided, in conformance with the City of Chicago Building Code, Section 16(13-52-040,) by considering each panel with one ply removed and subject to selfweight.
Describe the Service Design Loads:
· Public stairs: City of Chicago Building Code loads for public stairs were used, allowing 100 ponds per square foot simultaneously on all treads and the landing panel. Additional analysis allowed two 300-lb persons standing on any tread or the landing panel.
· Handrail loads: Concentrated load of 200 lbs in any direction at any point, or simultaneous vertical and horizontal thrust of 50 pounds per linear foot.
· Footstep sideway push: Allowed one 200-lb concentrated load on any tread.
· Footstep forward push: Allowed one 200-lb concentrated load on any tread.
· Wind pressure: Design wind pressure was determined to be 14.4 pounds per square foot, based on consideration of the staircase within a tall building, where sliding doors allow external wind pressure to influence the internal wind pressure.
Describe the Perimeter Vertical Panels:
· Role: The perimeter vertical panels provide overall stability, as well as gravity support, for the staircase.
· Level 39 supports: Each vertical panel was detailed to rest within a base channel, secured to Level 39 concrete floor slab. Analyses considered floor rotation that would reduce contact area. Base channel was designed to carry loads caused by horizontal loads, in any direction, and by vertical loads.
· Level 40 supports: Each vertical panel is supported against horizontal loads, in any direction, at Level 40. The Level 40 connection was detailed with a vertical slip, such that differential deflections of Level 40 and Level 39 induce no additional stresses within the glass panels.
Describe the Interior Vertical Panel:
· Role: Interior vertical panels provide gravity support, but do not contribute to the overall staircase stability. The interior vertical panels are laterally supported by the perimeter vertical panels, using the connecting treads as struts.
Describe the Treads and the Landing Panel:
· Role: The treads and the landing panel provide gravity support, and are also pin-connected to the vertical panels to allow participation within the overall staircase stability system.
· Steel clips: Each clip is detailed to allow rotation of the horizontal panel in relation to the supporting vertical panel. The steel clips are detailed to allow a soft, gentle transfer of loads from glass to steel, carefully avoiding hard spots.
FIG. 1 - Perimeter Vertical Panel Stress Profile, Subject to Combined Loads
FIG. 2 – Landing Panel Stress Profile, Subject to the Weights of Two 300-lb Persons